Leave Your Message
Products

Products

Products Categories
Featured Products
China Supplier Dental Surgery Furniture -
 Mobi... China Supplier Dental Surgery Furniture -
 Mobi...
01

China Supplier Dental Surgery Furniture - Mobi...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
OEM Supply Dental Handpiece -
 Digital 3D OPG P... OEM Supply Dental Handpiece -
 Digital 3D OPG P...
01

OEM Supply Dental Handpiece - Digital 3D OPG P...

2016-01-08
Pano: •Provide you with high diagnosis accuracy and better treatment on diseasesof the full dentiton and jaw. •Easy to get HD panoramic images by building a perfect tomographic track combined with the motion of the X, Y and Sita axis. CT : •A versatile helper to clearly display patient's anatomical structure with flexible FOV. •lntelligent imaging technology makes free observation from angle realizable. •Accurate measurement of the distance, area,volume and outline contour makes the one-key panoramic image obtained from the 3D image simple and easy. Cephalometric •Othodontic specialist's best choice making orthodontic treatment and maxillofacial surgery efficient and accurate. •Low-dose radiation and high gray realized by dual-level alignment adjustment to provide you with HD cephalometic images. •Unique algorithms of HRPBR image reconstruction and WE image processing •Leading technology intelligently generating HD pano images to provide with more clinical details and high diagnosis accuracy •Intelligent de-noise algorithm significantly improving image's resolution b yreducing image's noise and distortion •Variety of shooting modes: HD scanning, SD scanning, root canal scanning  •Special-designed algorithm of mental artifact removal providing with high quality images by removing artifacts caused by absorbent materials •CUDA high-speed image reconstruction High configuration and performance High Quality Flat Panel Detector Large surface and dynamic FPD ensure sensitivity and accuracy Metal Artifact Removal Effectively remove artifact caused by absorbent materials from the images with clearer details of human tissues displayed.
read more
Good Quality Children Dental Unit -
 Superior D... Good Quality Children Dental Unit -
 Superior D...
01

Good Quality Children Dental Unit - Superior D...

2016-01-08
1.Quiet and smooth two way with super soft medical ultra leather hydraulic patient chair  2.Articulating dual axis headrest 3.4 operator programmable position 4.Swing down armrest 5.LCD screen display aluminum casting base instrument tray with touch pad  6.3 handpiece automatic control & 2pcs three way syringe 7.Three axis led operating light with sensor 8.Electric controlled timed bowl rinse and cup filler 9.Swing arm ceramic bowl with touch button water activator 10.Sidebox with self-contained water system  11.Telescoping assistant arm with touch pad 12.Autoclavable standard HVE leaver valve with tubing  13.Autoclavable saliva ejector leaver valve with tubing  14.Asepsis three-way air/water syringe with tubing 15.Memory setting function foot control 16.Deluxe Dentist stool 1. Cast aluminum with steel reinforcement 2. LCD screens displays air/water pressures, water temperature,self contained clean water system / city water option. Along with date, time, and alarm setting  3. Synchronized back&seat movement 4. Safety emergency stop control device 5. Trendelenburg position    6. 30° left to right seat rotation 7. System anti-retraction valves to prevent cross contamination   8. Load capacity 250Kg   The leather of the chair cushion is made of USA imported medical materials, composed of ABS lining board + sponge material + imported medical artificial leather. Spittoon flushing and mouthwash cup water injection mode using 12V solenoid valve control, flow control accuracy. Intelligent memory set control, arbitrary adjustment of water cup and spittoon flush way and time. The instrument tray is connected with the lifting arm with a pneumatic self-locking position device. The shell is die-cast by aluminum alloy, and the horizontal alignment of the instrument tray can be adjusted arbitrarily. Equipped with LCD electronic screen, display information including water/air pressure, water temperature, cooling water conversion and working time, etc. 3-axis LED light with sensor. LED direct-injection dental lamp with universal rotating joint adjustment, switch with sensor and induction light intensity adjustment. Memory setting function foot control  Deluxe dentist stool Rotary shift hand support pillow. Stainless steel foot rings. Aluminum die-casting five - star foot support frame. The seat cushion and backrest cushion are sewn with ultra-leather imported from USA.
read more
2021 Good Quality Surgical Blade -
 Mobile Stan... 2021 Good Quality Surgical Blade -
 Mobile Stan...
01

2021 Good Quality Surgical Blade - Mobile Stan...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more