Leave Your Message
Products

Products

Products Categories
Featured Products
 Apixia Digital PSP Scanner USA Digital Imaging...  Apixia Digital PSP Scanner USA Digital Imaging...
01

Apixia Digital PSP Scanner USA Digital Imaging...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more
OEM Supply Dental Handpiece -
 Digital 3D OPG P... OEM Supply Dental Handpiece -
 Digital 3D OPG P...
01

OEM Supply Dental Handpiece - Digital 3D OPG P...

2016-01-08
Pano: •Provide you with high diagnosis accuracy and better treatment on diseasesof the full dentiton and jaw. •Easy to get HD panoramic images by building a perfect tomographic track combined with the motion of the X, Y and Sita axis. CT : •A versatile helper to clearly display patient's anatomical structure with flexible FOV. •lntelligent imaging technology makes free observation from angle realizable. •Accurate measurement of the distance, area,volume and outline contour makes the one-key panoramic image obtained from the 3D image simple and easy. Cephalometric •Othodontic specialist's best choice making orthodontic treatment and maxillofacial surgery efficient and accurate. •Low-dose radiation and high gray realized by dual-level alignment adjustment to provide you with HD cephalometic images. •Unique algorithms of HRPBR image reconstruction and WE image processing •Leading technology intelligently generating HD pano images to provide with more clinical details and high diagnosis accuracy •Intelligent de-noise algorithm significantly improving image's resolution b yreducing image's noise and distortion •Variety of shooting modes: HD scanning, SD scanning, root canal scanning  •Special-designed algorithm of mental artifact removal providing with high quality images by removing artifacts caused by absorbent materials •CUDA high-speed image reconstruction High configuration and performance High Quality Flat Panel Detector Large surface and dynamic FPD ensure sensitivity and accuracy Metal Artifact Removal Effectively remove artifact caused by absorbent materials from the images with clearer details of human tissues displayed.
read more
China Cheap price Barrier Film -
 Mobile Stand ... China Cheap price Barrier Film -
 Mobile Stand ...
01

China Cheap price Barrier Film - Mobile Stand ...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Fast delivery Air/Water Syringe Tip -
 JP-STE-8... Fast delivery Air/Water Syringe Tip -
 JP-STE-8...
01

Fast delivery Air/Water Syringe Tip - JP-STE-8...

2016-01-08
Meeting to EN13060 European standard With pre-post vacuum Quick cycle only 10-12min LED display User friendly interface Double locking system Easily accessible water tank 2 trays, max 5 optional Multiple languages Power: 1500W Size: 414*365*530mm Tray size: 147*265mm Cavity size: Φ170x320mm 1.Microcomputer control system for automatic check; 2.With precise control, the temperature can be controlled within ± 0.5 during sterilizing 3.Friendly operation interface, simply and easy 4.B&D test, vacuum test, convenient for machine behave test 5.Automatical record of the time of sterilization beginning &end. Clean the inner pipe automatically for avoiding jam after every 6.100 times of cycles. 6.The dry time is adjustable according to your will 7.The machine is dual-purpose, not only for instruments,but also for cotton, on dry condition 8.With a LED display 9.Adjustable date&time&language mode according to your will 10.Opened reservoir, convenient for cleaning, avoiding chloramphenicol alive 11.Water quality sensor can test the quality of distilled water, reduce the failure rate 12.One-piece chamber is made of imported 304 stainless steel 13.Safety valve ensure the chamber can release the pressure safely at emergency 14.Double doors locking-system, mechanical lock with electrical lock,the machine can't open until the pressure turn 0 15.Multi-safety protection system, which can ensure the safety of the operator 16.Air-conditional heat removal system, prevent the machine from over-heating 17.Adopt the ABS plastic, whole model produce 18.The machine plane can adjust by adjustable pad, provide a gradienter for free 19.Optional printer, with a internal USB module as standard collocation to record the sterilization process
read more
Top Suppliers Electric Dental Scaler -
 Apixia ... Top Suppliers Electric Dental Scaler -
 Apixia ...
01

Top Suppliers Electric Dental Scaler - Apixia ...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more
Super Lowest Price X-ray Sensors Cover -
 Porta... Super Lowest Price X-ray Sensors Cover -
 Porta...
01

Super Lowest Price X-ray Sensors Cover - Porta...

2016-01-08
This portable dental X-ray unit is high frequency machine. The body is small, light weight and nearly no radiation. It has excellent image quality, portable storage, save more space. It uses high frequency and DC international power supply. All of the components installed in the central PC board concentrated. Shock, set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. There are also manual buttons installed on the surface of shell, as well as batteries and charges. This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. It also can connect with sensor, is great convenience. Checking and Security !  Caution: Please learn relative security measures and functions given in the file or on the unit. * Using the products after checking battery and the location of the device, make sure that is operates properly. * Checking all the power cords whether correctly and connected formally. * Operating the device in the designated order. * Recheck the cone connect with the patient’s face closely. * Keep the device and the cone clean. * Please use or operate the device and parts after taking a necessary periodic inspection. * If you discover some difference in the sensor images even if you inspected its x-ray exposure time in the same way as before, then it means that the radiation of x-ray is abnormal, you must stop using it immediately and allow it to be inspected. * Don’t use or store near the place which is possible to fire. * Don’t use or store where air pressure or temperature or moisture exceeds range. * Keep good ventilation and avoid direct sunlight, protect against the eroding of dust and corrosive air. * Don’t use or store near to chemicals or combustible gas. Tube voltage 60KV Tube current 1.5mA Exposure time 0.1--2.0s Frequency 30KHz Rate power 60VA Distance from skin to cone 130mm Tube focus 0.3mm*0.3mm Battery DC14.8V  6400mAh Charger input voltage AC100V-240V±10% Output voltage DC16.8V Ambient temperature 5℃~40℃ Relative temperature <75%RH Net weight 2.5KG Gross weight 3.5KG Size(mm) 138*165*185 Package size(mm) 365*330*265
read more
Trending Products Dentist Simulator -
 Portable... Trending Products Dentist Simulator -
 Portable...
01

Trending Products Dentist Simulator - Portable...

2016-01-08
This portable dental X-ray unit is high frequency machine. The body is small, light weight and nearly no radiation. It has excellent image quality, portable storage, save more space. It uses high frequency and DC international power supply. All of the components installed in the central PC board concentrated. Shock, set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. There are also manual buttons installed on the surface of shell, as well as batteries and charges. This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. It also can connect with sensor, is great convenience. Checking and Security !  Caution: Please learn relative security measures and functions given in the file or on the unit. * Using the products after checking battery and the location of the device, make sure that is operates properly. * Checking all the power cords whether correctly and connected formally. * Operating the device in the designated order. * Recheck the cone connect with the patient’s face closely. * Keep the device and the cone clean. * Please use or operate the device and parts after taking a necessary periodic inspection. * If you discover some difference in the sensor images even if you inspected its x-ray exposure time in the same way as before, then it means that the radiation of x-ray is abnormal, you must stop using it immediately and allow it to be inspected. * Don’t use or store near the place which is possible to fire. * Don’t use or store where air pressure or temperature or moisture exceeds range. * Keep good ventilation and avoid direct sunlight, protect against the eroding of dust and corrosive air. * Don’t use or store near to chemicals or combustible gas. Tube voltage 60KV Tube current 1.5mA Exposure time 0.1--2.0s Frequency 30KHz Rate power 60VA Distance from skin to cone 130mm Tube focus 0.3mm*0.3mm Battery DC14.8V  6400mAh Charger input voltage AC100V-240V±10% Output voltage DC16.8V Ambient temperature 5℃~40℃ Relative temperature <75%RH Net weight 2.5KG Gross weight 3.5KG Size(mm) 138*165*185 Package size(mm) 365*330*265
read more
Good Quality Dental Suction -
 Best Price High ... Good Quality Dental Suction -
 Best Price High ...
01

Good Quality Dental Suction - Best Price High ...

2016-01-08
Dental Vacuum Suction 2 Dental Vacuum Suction 4 Dental Vacuum Suction 5 When dentists prepare the teeth, a large number of bacterium-carrying airflow (atomized state) ejected from patients is directly sprayed to the face of dentists, and spreads to the whole oral examination room, polluting the environment;According to statistics, dentists are the most susceptible of infection among all practicing physicians;In the course of treatment, inevitably there are a lot of water into the patient's mouth (turbine handpiece cooling water and clean the wound clean water, etc.), and the patient's own secretion, will stimulate the patient's nerve, cause swallowing reaction, such as cannot be sustained and effective drainage, will stop treatment;The vacuum suction of the traditional dental unit adopts the principle of "jet flow". The compressed air or water is discharged in large quantities in the main pipe, so that the negative pressure formed by vacuum in the auxiliary pipe is used to suck the fluid in the patient's mouth.If the compressed air is used as power, it will cause the continuous operation of the compressor and reduce the service life of the compressor.If urban tap water is used as power, water resources will be greatly lost, energy will be wasted and operating costs of clinics will be increased. The HVS series dental electric suction system vacuum pump manufactured by our company adopts the structure form of impeller directly mounted on the motor rotor, which is completely contactless compression. Because the pump bearing is installed outside the compression chamber, it can ensure the reliable work of the machine even under the maximum pressure difference. 1.Suction & Exhausting In Same Time, No Suction Blind Spot. 2.Last Long & Comfort Suction Power.Protect Working Conditions For Both Doctors & Patients. 3.Suction delay function ensures no residue in the pipeline 4.Good heat dissipation performance, stable and large suction, no waste water and no bacteria. 5.Less Space Needed,Less Consumption&Less Noise. 6.Easy Maintenance & Longer Use Life. 7.Waste water is disinfected, environment friendly. 8.Inverter system can be added,timely adjust the working frequency, no water circulation, saving energy and reducing costs 9.Reduce the gas consumption in the clinic..Prolongs the service life of the compressor and reduces the amount of configuration of the compressor MODEL VOLTAGE Suction capacity Max negative pressure JPCX-10 380V 3000L/min ≤ -16KPA Rated Power Noise level Weight Measurement 3.3kW(inverter) 76dB(A) 117kg 80*60*97cm Model Voltage (V/Hz) Rated Power (KW) Vacuum (KPa) Max Suction (m³/min) JPCX-01 220/50 0.75 ≤-12 0.3 380/50 JPCX-02 220/50 1.3 ≤-13 0.9 380/50 JPCX-03 220/50 1.5 ≤-14 1.5 380/50 JPCX-05 220/50 1.9 ≤-15 1.5 380/50 JPCX-07 380/50 2.5 ≤-15 2.1 JPCX-10 380/50 3.3 ≤-16 3.0  
read more