Leave Your Message
Products

Products

Products Categories
Featured Products
PriceList for Teeth Model -
 High quality Denta... PriceList for Teeth Model -
 High quality Denta...
01

PriceList for Teeth Model - High quality Denta...

2016-01-08
Designed for the simulation of clinical education Designed for the simulation of clinical education, help students develop the right operating posture in the pre-clinical study, master ergonomic skills and then smoothly transition to real clinical treatment. With JPS FT-III dental teaching simulation system, students learn right from the start, under more realistic conditions: •In a pre-clinical environment, students learn using standard treatment centre components and do not have to adjust to new equipment later in their education •Optimum treatment ergonomics with height-adjustable dentist and assistant elements •Best protection of student health, with integrated, continuous and intensive disinfection of internal water-lines •New design: dual instrument tray, makes four-hand operation come true . •Operation light: the brightness is adjustable. With different type teeth mode Manikin comes with magnetic articulator , it is compatible with different type teeth model Imitate real clinical environment. Electric motors drive the movement of the manikin----imitate real clinical environment. Easy to clean Auto reset function of manikin system- provide the cleanliness and utilization of space Artificial marble top is easy to clean Two preset position keys Two preset position keys : S1 , S2 Automatic reset key : S0 Can be set highest and lowest position With emergency stop function Hommization Suction water bottle Suction water bottle is designed to be removed and installed very easily ,improve study efficiency a lot. JPS Dental simulation experts, reliable partners, sincere forever!
read more
2021 China New Design Disposable Dental Trays -... 2021 China New Design Disposable Dental Trays -...
01

2021 China New Design Disposable Dental Trays -...

2016-01-08
Specification: Model                  Description For all HP style 50ml impression material cartridges DTA3100             Yellow, 4.2mm DTA3110             Pink, 5.4mm DTA3120             Green, 6.5mm DTA3130             Purple, 7.5mm, with    Monophase and Heavy For temporary crowns,bridges and acrylics with three different kinds of ratios including 10:1,4:1 and 1:1 DTA3140            Blue/Orange-10:1 and 4:1 Ratio DTA3150            Blue/Clear-1:1  Long tapered, DTA3160            Blue/Clear-1:1 Short blunt High Performance Mixing Tips for temporary cement with 1:1 ratio DTA3180           Short Tapered, Brown-1:1 Ratio DTA3185           Short Blunt, Brown-1:1 Ratio For use with automatic impression material mixing systems. DTA3170           Dynamic Intraoral Tips fiiting with any universal mixing tips DTA3190          Yellow Color DTA3193          Small Opening DTA3196          Large Opening DTA3198/DTA3199     fitting with DTA3185 Both types of dispensing guns are used to extrude impression materials and bite registration materials from cartridge.Each of them consists of a release lever and a plunger,which are coordinated simultaneously to load and remove the cartridge.DTA0745 work with 1:1 and 1:2 cartridges while DTA0746 with 1:4 and 1:10.Perfect Performance with our series of Mixing Tips!
read more
Wholesale Price China Induction Casting Machine... Wholesale Price China Induction Casting Machine...
01

Wholesale Price China Induction Casting Machine...

2016-01-08
This type of Dental workstation widely adopts some famous dental technicians' advice both at home and abroad.The main material consists of cold-rolled stamping, die-casting aluminium alloy and extrusions.Through 3D modeling design, and by laser cutting machine,CNC bending machine, automatic welding machine and other modern equipment precision machining.Surface material can be made by squeezed high-density fireproof board, or stainless steel, or man-made marble.Selves on the desk are all made by aluminium alloy, which make the selves elegant and durable.The work light is combined by sun-light source and 5- inch 300-degree magnifier.Elbow guard surface is covered by elastomer material which makes the elbow more comfortable.The elbow working space can be adjusted in two levels between standard (40cm) and widen (48cm).Hand Gurad Layer Board adjustable any 5-20angle range.Self-reset air gun is well designed with good texture.The independent suction device also supports central vacuuming system which has strong power and low noise.The height of this desk can be adjusted between 80cm and 85cm.The four corners can be fine-tuned according to the ground.The delicate appearance air gun can reset automatic. The workstation configures low noise and suction power dust exhaust apparatus, also it support central dust collection system concentrated dust collection.Embedded integrated electrical control box is easy to fix and replace.This control box can control all of the electrical circuit, at the same time, based on this control box and from the digital window; workers can check the vacuum dust collection system of the motor run time.The standard configuration USB interface can support 2A 12V weak power.The suction nozzle assembly has two accessories can choose.One is Fan toughened glass block dust board another one is LED lamp ring (built-5 inch magnifying glass/5 inch flat lens). The workstation has a unique hidden layer, which is neat and easy to use, and can be used in the actual use of all pipelines, as well as vacuum cleaners are hidden in the sandwich.Between each workstations can connect seamlessly.There are supplementary dust collection components which are allocated randomly.The operation desk can be cleaned just by buckling the assistant suction device on the nozzle.
read more
Factory Free sample Curing Light -
 Planmeca Pr... Factory Free sample Curing Light -
 Planmeca Pr...
01

Factory Free sample Curing Light - Planmeca Pr...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
Fixed Competitive Price Simple Manikin -
 Mobil... Fixed Competitive Price Simple Manikin -
 Mobil...
01

Fixed Competitive Price Simple Manikin - Mobil...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more