Leave Your Message
Products

Products

Products Categories
Featured Products
Wholesale Price Base Plate Wax -
 Planmeca Prom... Wholesale Price Base Plate Wax -
 Planmeca Prom...
01

Wholesale Price Base Plate Wax - Planmeca Prom...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
Good Quality Children Dental Unit -
 AM100 Algi... Good Quality Children Dental Unit -
 AM100 Algi...
01

Good Quality Children Dental Unit - AM100 Algi...

2016-01-08
Voltage: 220V-240V/50HZ-60HZ         Power:400W          Revolution:3000r.p.m/50HZ; 3000r.p.m/60HZ Scope of timing:4-16s Mode of Memory:5 kinds Automatic computer control & Numeral display 5 pre-set programs Fit for different moulage material and different mixed dosage 1. Imported motor, low noise and long service life 2. Microcomputer control, safe and reliable operation; 3. After mixing, the impression material has no bubbles, good elasticity, not easy to deform, and mold taking is clearer; 4. The setting time range is long, within 1-24 seconds, the user can choose according to the characteristics of different impression materials; 5. Three kinds of computer memories can be set according to user needs (the factory setting is 8 seconds "one spoon of powder", 10 seconds two spoons of powder", 12 seconds "three spoons of powder">; 6. The internal temperature control of the product is reliable, and it can work continuously for a long time without affecting the production of impression materials; it runs with low noise and is easy to operate. (1) There is a vent hole on the top of the mixing bowl cover. Please clean it to ensure that it is not blocked by impression powder and other sundries. (2) The weight of each mixing (total weight of water and impression powder) should be 25g-75g. If the weight of the mixture is out of this range, the noise of the machine will increase, and there will even be abnormal noises such as impacts, which may damage the machine in severe cases. (3) The optimal mixing weight designed for this machine is 58g , which is the best state of the machine at this time. (4) For the ratio of impression powder and water during mixing, please refer to the standard of the impression powder manufacturer. The supplied water bottle can help measure the amount of water required. Unscrew the bottle body and fill it with mixing water. After tightening, squeeze the bottle body by hand to measure the amount of water (you can also use the special instrument provided by the impression powder manufacturer to measure. According to our experience, a slight increase in the proportion of water will make The mixed impression powder is more delicate, but this will slightly increase the curing time). (5) The temperature of the stirring water should be 10-20°C, otherwise the curing time will be shortened, which is not conducive to operation (especially in summer).
read more
China wholesale Implant Packs -
 JPU-600D Ultra... China wholesale Implant Packs -
 JPU-600D Ultra...
01

China wholesale Implant Packs - JPU-600D Ultra...

2016-01-08
The ultrasonic cleaner is a microprocessor-controlled device that uses ultrasonic or high frequency sound waves to clean jewelry and other delicate items. Ultrasonic cleaning is based on the cavitation effect caused by high frequency ultrasonic wave vibration signals in fluid. Microscopic bubbles that expand and rapidly collapse cause cavitation, which creates an effective cleaning action on the surface of object being cleaned. Additionally, the bubbles are small enough to penetrate even microscopic crevices, cleaning them thoroughly and consistently.  High efficiency saves cleaning solvent, thermal energy, work place and labor!  Three sets of built-in powerful transducers can strengthen the ultrasonic power and make superior cleaning outcome. It is utilization of digital program in ultrasonic cleaner to control the unit, according to the quantity and condition of the items to be cleaned to choose a working cycle time. As a result, it is more convenient and efficient than hand wash, steam cleaners, high pressure water jet cleaning or other machines. Advanced Brushed Stainless Steel Cleaning Tank to avoid corrosion water stain and keep the tank looking always new. (In comparison, the common stainless steel cleaning tanks will be dirty yellow corrosion water stain on the surface after a long time of using, and it's hard to be removed.) Power Voltage: AC220V/50Hz or AC110V/60Hz Fuse Tube: 2A, 250V Ultrasonic Power: 120W Heating Power: 150W Time: 1~99Minutes Temperature:20℃ ~ 80℃ Dimension of Cleaning Slot: 24*14*15cm Professional Use: Medical and Dental Clinics, Tattoo Shops, Scientific Labs and Golf Clubs. Jewelers, Opticians, Watchmakers, Antique Dealers and Electronics Workshops etc.
read more
Professional China Glass Dappen Dish -
 Apixia ... Professional China Glass Dappen Dish -
 Apixia ...
01

Professional China Glass Dappen Dish - Apixia ...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more
Manufacturer of Dental Endo Motor -
 Mobile Sta... Manufacturer of Dental Endo Motor -
 Mobile Sta...
01

Manufacturer of Dental Endo Motor - Mobile Sta...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Europe style for Dental Furniture -
 Mobile Sta... Europe style for Dental Furniture -
 Mobile Sta...
01

Europe style for Dental Furniture - Mobile Sta...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more