Leave Your Message
Products

Products

Products Categories
Featured Products
Good quality Cotton Roll -
 Planmeca Promax 2D ... Good quality Cotton Roll -
 Planmeca Promax 2D ...
01

Good quality Cotton Roll - Planmeca Promax 2D ...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
Hot sale Dental Bib Clip -
 Planmeca Promax 2D ... Hot sale Dental Bib Clip -
 Planmeca Promax 2D ...
01

Hot sale Dental Bib Clip - Planmeca Promax 2D ...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
8 Year Exporter Dental Curing Light -
 Mobile S... 8 Year Exporter Dental Curing Light -
 Mobile S...
01

8 Year Exporter Dental Curing Light - Mobile S...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
China Cheap price Dental Oil Free Air Compresso... China Cheap price Dental Oil Free Air Compresso...
01

China Cheap price Dental Oil Free Air Compresso...

2016-01-08
Our air compressor is from one of the toppest brand in China. 20 years of production experience, unique product design and process application and perfect management system ensure the stable quality of products and establish the position of our brand in the field of oil-free air compressor. Air compressor is a commonly used machine in production equipment. It is no stranger to many enterprises.But for the choice of air compressor brand, many customers are often in a tangle of contradictions.Silent oil-free air compressor is a small piston type air compressor, often called silent oil-free air compressor.Medical silent oil-free air compressor generally needs high quality compressed gas. The machine needs strong reliability, silence, and the output air can directly contact the human body. Our oil-free compressor is specially designed for supplying oil-free dry healthy medical grade clean air in medical field. Especially in oral clinic and hospital, it can satisfy the demands from one to hundreds of dental chairs, suitable for different request. Silent box, dryer and filtration system can be added, so as to reduce the noise, improve the pressure dew point and filter accuracy.  1.Oil Free Design For Stable Oil Free Air Supplying. 2.Automatic Start-Stop Controlled By Pressure Switch, prevent burn out, ensure the safety of use. 3.Promise to adopt pure copper coil, good heat dissipation and long service life. 4.4mm air tank thickness, inner and outer fully sprayed with plastic. 5.Adopt precision parts, important parts have CE certification to ensure product quality. 6.Special plastic spraying process, good corrosion resistance 7.Could be used when the power is connected. 8.No need lubricate oil for maintenance. 9.Single phase and three phases with low fault rate and longer usage life. 10.Easy operation, low fault rate and long service life. MODEL VOLTAGE MAX AIR FLOW MAX PRESSURE YHT-200 220V 300L/min 0.75Mpa Rated Power Rotation Tank Measurement 750W*2 1450RPM 60L 720*400*700mm Model Voltage (V/Hz) Input Power (KW) Rated Discharge Pressure (MPa) Rated Air Flow (m³/L) YH-100 220/50/1 550 0.7 2.0 YH-200 220/50/1 750 0.7 3.0 YHT-200 220/50/1 750*2 0.7 6.0 YH-300 220/50/1 1100 0.7 4.5 YHT-300 220/50/1 1100*2 0.7 9.0 YH-400 380/50/3 750*3 0.7 9.0 YHT-400 380/50/3 1100*3 0.7 13.5 YH-500 380/50/3 750*4 0.7 12.0 YHT-500 380/50/3 1100*4 0.7 18.0 Dental oiless compressor is a commonly used machine in oral clinic and hospital. It is no strange to many enterprises. But when it comes to the choice of dental air compressor brand, many customers are often in a tangle of contradictions. Silent oil-free air compressor is a small piston type air compressor, usually called silent oil-free air compressor.Medical silent oil-free air compressor generally needs high quality compressed gas. The machine needs strong reliability, silence, and the output gas can directly contact the human body. Our oil-free compressor is professionally designed for supplying dry oil-free healthy medical grade clean air in medical field. Especially in oral clinic and hospital, it can satisfy the needs from different quantity of dental chairs, suitable for different request. Silent box, dryer and filtration system can be added, so as to reduce the noise, improve the pressure dew point and filter accuracy.  1. Large capacity to supply 7-9units dental chairs. 2. Three separated electric motors design, can keep working even one is broken. 3. Oil free design for healthy oil free Air supplying. 4. Automatic Start-Stop , prevent burn out, ensure the safety of use. 5. Pure copper coil with good heat dissipation and long service life. 6. 4mm air tank thickness fully sprayed with plastic. 7. Special plastic spraying process, good corrosion resistance 8. No need lubricate oil for maintenance.
read more
18 Years Factory Combined Dental Cabinets -
 Pl... 18 Years Factory Combined Dental Cabinets -
 Pl...
01

18 Years Factory Combined Dental Cabinets - Pl...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
 Best Price High Quality Separated Dental Vacuu...  Best Price High Quality Separated Dental Vacuu...
01

Best Price High Quality Separated Dental Vacuu...

2016-01-08
Dental Vacuum Suction 2 Dental Vacuum Suction 4 Dental Vacuum Suction 5 When dentists prepare the teeth, a large number of bacterium-carrying airflow (atomized state) ejected from patients is directly sprayed to the face of dentists, and spreads to the whole oral examination room, polluting the environment;According to statistics, dentists are the most susceptible of infection among all practicing physicians;In the course of treatment, inevitably there are a lot of water into the patient's mouth (turbine handpiece cooling water and clean the wound clean water, etc.), and the patient's own secretion, will stimulate the patient's nerve, cause swallowing reaction, such as cannot be sustained and effective drainage, will stop treatment;The vacuum suction of the traditional dental unit adopts the principle of "jet flow". The compressed air or water is discharged in large quantities in the main pipe, so that the negative pressure formed by vacuum in the auxiliary pipe is used to suck the fluid in the patient's mouth.If the compressed air is used as power, it will cause the continuous operation of the compressor and reduce the service life of the compressor.If urban tap water is used as power, water resources will be greatly lost, energy will be wasted and operating costs of clinics will be increased. The HVS series dental electric suction system vacuum pump manufactured by our company adopts the structure form of impeller directly mounted on the motor rotor, which is completely contactless compression. Because the pump bearing is installed outside the compression chamber, it can ensure the reliable work of the machine even under the maximum pressure difference. 1.Suction & Exhausting In Same Time, No Suction Blind Spot. 2.Last Long & Comfort Suction Power.Protect Working Conditions For Both Doctors & Patients. 3.Suction delay function ensures no residue in the pipeline 4.Good heat dissipation performance, stable and large suction, no waste water and no bacteria. 5.Less Space Needed,Less Consumption&Less Noise. 6.Easy Maintenance & Longer Use Life. 7.Waste water is disinfected, environment friendly. 8.Inverter system can be added,timely adjust the working frequency, no water circulation, saving energy and reducing costs 9.Reduce the gas consumption in the clinic..Prolongs the service life of the compressor and reduces the amount of configuration of the compressor MODEL VOLTAGE Suction capacity Max negative pressure JPCX-10 380V 3000L/min ≤ -16KPA Rated Power Noise level Weight Measurement 3.3kW(inverter) 76dB(A) 117kg 80*60*97cm Model Voltage (V/Hz) Rated Power (KW) Vacuum (KPa) Max Suction (m³/min) JPCX-01 220/50 0.75 ≤-12 0.3 380/50 JPCX-02 220/50 1.3 ≤-13 0.9 380/50 JPCX-03 220/50 1.5 ≤-14 1.5 380/50 JPCX-05 220/50 1.9 ≤-15 1.5 380/50 JPCX-07 380/50 2.5 ≤-15 2.1 JPCX-10 380/50 3.3 ≤-16 3.0  
read more
Chinese Professional Gutta Percha Points -
 Mob... Chinese Professional Gutta Percha Points -
 Mob...
01

Chinese Professional Gutta Percha Points - Mob...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more