Leave Your Message
Products

Products

Products Categories
Featured Products
Best quality Zinc-Oxide Eugenol Cement -
 Planm... Best quality Zinc-Oxide Eugenol Cement -
 Planm...
01

Best quality Zinc-Oxide Eugenol Cement - Planm...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
OEM Factory for Autoclavable Spatula -
 JP-STE-... OEM Factory for Autoclavable Spatula -
 JP-STE-...
01

OEM Factory for Autoclavable Spatula - JP-STE-...

2016-01-08
Meeting to EN13060 European standard With pre-post vacuum Quick cycle only 10-12min LED display User friendly interface Double locking system Easily accessible water tank 2 trays, max 5 optional Multiple languages Power: 1500W Size: 414*365*530mm Tray size: 147*265mm Cavity size: Φ170x320mm 1.Microcomputer control system for automatic check; 2.With precise control, the temperature can be controlled within ± 0.5 during sterilizing 3.Friendly operation interface, simply and easy 4.B&D test, vacuum test, convenient for machine behave test 5.Automatical record of the time of sterilization beginning &end. Clean the inner pipe automatically for avoiding jam after every 6.100 times of cycles. 6.The dry time is adjustable according to your will 7.The machine is dual-purpose, not only for instruments,but also for cotton, on dry condition 8.With a LED display 9.Adjustable date&time&language mode according to your will 10.Opened reservoir, convenient for cleaning, avoiding chloramphenicol alive 11.Water quality sensor can test the quality of distilled water, reduce the failure rate 12.One-piece chamber is made of imported 304 stainless steel 13.Safety valve ensure the chamber can release the pressure safely at emergency 14.Double doors locking-system, mechanical lock with electrical lock,the machine can't open until the pressure turn 0 15.Multi-safety protection system, which can ensure the safety of the operator 16.Air-conditional heat removal system, prevent the machine from over-heating 17.Adopt the ABS plastic, whole model produce 18.The machine plane can adjust by adjustable pad, provide a gradienter for free 19.Optional printer, with a internal USB module as standard collocation to record the sterilization process
read more
2021 wholesale price Safety Glasses -
 Mobile S... 2021 wholesale price Safety Glasses -
 Mobile S...
01

2021 wholesale price Safety Glasses - Mobile S...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Top Quality Modern Dental Cabinets -
 Mobile St... Top Quality Modern Dental Cabinets -
 Mobile St...
01

Top Quality Modern Dental Cabinets - Mobile St...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Reasonable price Neaten Cases -
 Digital 3D OPG... Reasonable price Neaten Cases -
 Digital 3D OPG...
01

Reasonable price Neaten Cases - Digital 3D OPG...

2016-01-08
Pano: •Provide you with high diagnosis accuracy and better treatment on diseasesof the full dentiton and jaw. •Easy to get HD panoramic images by building a perfect tomographic track combined with the motion of the X, Y and Sita axis. CT : •A versatile helper to clearly display patient's anatomical structure with flexible FOV. •lntelligent imaging technology makes free observation from angle realizable. •Accurate measurement of the distance, area,volume and outline contour makes the one-key panoramic image obtained from the 3D image simple and easy. Cephalometric •Othodontic specialist's best choice making orthodontic treatment and maxillofacial surgery efficient and accurate. •Low-dose radiation and high gray realized by dual-level alignment adjustment to provide you with HD cephalometic images. •Unique algorithms of HRPBR image reconstruction and WE image processing •Leading technology intelligently generating HD pano images to provide with more clinical details and high diagnosis accuracy •Intelligent de-noise algorithm significantly improving image's resolution b yreducing image's noise and distortion •Variety of shooting modes: HD scanning, SD scanning, root canal scanning  •Special-designed algorithm of mental artifact removal providing with high quality images by removing artifacts caused by absorbent materials •CUDA high-speed image reconstruction High configuration and performance High Quality Flat Panel Detector Large surface and dynamic FPD ensure sensitivity and accuracy Metal Artifact Removal Effectively remove artifact caused by absorbent materials from the images with clearer details of human tissues displayed.
read more
Factory source Intra Oral Camera -
 Digital 3D ... Factory source Intra Oral Camera -
 Digital 3D ...
01

Factory source Intra Oral Camera - Digital 3D ...

2016-01-08
Pano: •Provide you with high diagnosis accuracy and better treatment on diseasesof the full dentiton and jaw. •Easy to get HD panoramic images by building a perfect tomographic track combined with the motion of the X, Y and Sita axis. CT : •A versatile helper to clearly display patient's anatomical structure with flexible FOV. •lntelligent imaging technology makes free observation from angle realizable. •Accurate measurement of the distance, area,volume and outline contour makes the one-key panoramic image obtained from the 3D image simple and easy. Cephalometric •Othodontic specialist's best choice making orthodontic treatment and maxillofacial surgery efficient and accurate. •Low-dose radiation and high gray realized by dual-level alignment adjustment to provide you with HD cephalometic images. •Unique algorithms of HRPBR image reconstruction and WE image processing •Leading technology intelligently generating HD pano images to provide with more clinical details and high diagnosis accuracy •Intelligent de-noise algorithm significantly improving image's resolution b yreducing image's noise and distortion •Variety of shooting modes: HD scanning, SD scanning, root canal scanning  •Special-designed algorithm of mental artifact removal providing with high quality images by removing artifacts caused by absorbent materials •CUDA high-speed image reconstruction High configuration and performance High Quality Flat Panel Detector Large surface and dynamic FPD ensure sensitivity and accuracy Metal Artifact Removal Effectively remove artifact caused by absorbent materials from the images with clearer details of human tissues displayed.
read more
2021 High quality Hydraulic Dental Chair -
 Wel... 2021 High quality Hydraulic Dental Chair -
 Wel...
01

2021 High quality Hydraulic Dental Chair - Wel...

2016-01-08
abide by the contract", conforms on the market requirement, joins within the market competition by its good quality at the same time as provides far more comprehensive and great company for customers to let them grow to be major winner. The pursue in the company, will be the clients' pleasure for Well-designed China Disposable 100% Pure Dental Cotton Roll, With a quickly enhancement and our customers come from Europe, United States, Africa and everywhere in the world. Welcome to go to our manufacturing unit and welcome your get, for more inquires be sure to never hesitate to get in touch with us! abide by the contract", conforms on the market requirement, joins within the market competition by its good quality at the same time as provides far more comprehensive and great company for customers to let them grow to be major winner. The pursue in the company, will be the clients' pleasure for China Dental Cotton Roll, Disposable Dental Cotton Roll, Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation. 100% absorbent cotton More soft, more absorbency Available in multiple package; non-sterile and sterile To comply with USP, BP, EP etc [Description] 8X25mm...............50/bundle, 40bundle/box, 10boxes/ctn 10X30mm.............50/bundle, 40bundle/box, 10boxes/ctn 10X38mm.............50/bundle, 40bundle/box, 10boxes/ctn L 1-1/2”X1/2”.......50/bundle, 40bundle/box, 10boxes/ctn M 1-1/2”X3/8”.......50/bundle, 40bundle/box, 10boxes/ctn S 1-1/2”X5/16”.....50/bundle, 40bundle/box, 10boxes/ctn abide by the contract", conforms on the market requirement, joins within the market competition by its good quality at the same time as provides far more comprehensive and great company for customers to let them grow to be major winner. The pursue in the company, will be the clients' pleasure for Well-designed China Disposable 100% Pure Dental Cotton Roll, With a quickly enhancement and our customers come from Europe, United States, Africa and everywhere in the world. Welcome to go to our manufacturing unit and welcome your get, for more inquires be sure to never hesitate to get in touch with us! Well-designed China Dental Cotton Roll, Disposable Dental Cotton Roll, Our stock have valued 8 million dollar , you can find the competitive parts within short delivery time. Our company is not only your partner in business, but also our company is your assistant in the coming corporation.
read more
Renewable Design for Dental Simulator -
 Mobile... Renewable Design for Dental Simulator -
 Mobile...
01

Renewable Design for Dental Simulator - Mobile...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more