Leave Your Message
Products

Products

Products Categories
Featured Products
Good Quality Dental Suction -
 Best Price High ... Good Quality Dental Suction -
 Best Price High ...
01

Good Quality Dental Suction - Best Price High ...

2016-01-08
When dentists prepare the teeth, a large number of bacterium-carrying airflow (atomized state) ejected from patients is directly sprayed to the face of dentists, and spreads to the whole oral examination room, polluting the environment;According to statistics, dentists are the most susceptible of infection among all practicing physicians;In the course of treatment, inevitably there are a lot of water into the patient's mouth (turbine handpiece cooling water and clean the wound clean water, etc.), and the patient's own secretion, will stimulate the patient's nerve, cause swallowing reaction, such as cannot be sustained and effective drainage, will stop treatment;The vacuum suction of the traditional dental unit adopts the principle of "jet flow". The compressed air or water is discharged in large quantities in the main pipe, so that the negative pressure formed by vacuum in the auxiliary pipe is used to suck the fluid in the patient's mouth.If the compressed air is used as power, it will cause the continuous operation of the compressor and reduce the service life of the compressor.If urban tap water is used as power, water resources will be greatly lost, energy will be wasted and operating costs of clinics will be increased. The HVS series dental electric suction system vacuum pump manufactured by our company adopts the structure form of impeller directly mounted on the motor rotor, which is completely contactless compression. Because the pump bearing is installed outside the compression chamber, it can ensure the reliable work of the machine even under the maximum pressure difference. 1.Suction & Exhausting In Same Time, No Suction Blind Spot. 2.Last Long & Comfort Suction Power.Protect Working Conditions For Both Doctors & Patients. 3.Suction delay function ensures no residue in the pipeline 4.Good heat dissipation performance, stable and large suction, no waste water and no bacteria. 5.Less Space Needed,Less Consumption&Less Noise. 6.Easy Maintenance & Longer Use Life. 7.Waste water is disinfected, environment friendly. 8.Inverter system can be added,timely adjust the working frequency, no water circulation, saving energy and reducing costs 9.Reduce the gas consumption in the clinic..Prolongs the service life of the compressor and reduces the amount of configuration of the compressor MODEL VOLTAGE Suction capacity Max negative pressure JPCX -03 (Wet) 110V/220V 1500L/min ≤ -14KPA Rated Power Noise level Weight Measurement 1.5kW(inverter) 69dB(A) 40kg 50*38*65cm Model Voltage (V/Hz) Rated Power (KW) Vacuum (KPa) Max Suction (m³/min) JPCX-01 220/50 0.75 ≤-12 0.3 380/50 JPCX-02 220/50 1.3 ≤-13 0.9 380/50 JPCX-03 220/50 1.5 ≤-14 1.5 380/50 JPCX-05 220/50 1.9 ≤-15 1.5 380/50 JPCX-07 380/50 2.5 ≤-15 2.1 JPCX-10 380/50 3.3 ≤-16 3.0  
read more
2021 Good Quality Portable X-ray Unit -
 Econom... 2021 Good Quality Portable X-ray Unit -
 Econom...
01

2021 Good Quality Portable X-ray Unit - Econom...

2016-01-08
Standard Specification: Electronic control panel on the the instrument tray Handpiece hoses 3pcs 3-way syringe 2pcs X-ray film viewer Integrated ceramic cuspidor Cup-filler & bowl rinse Air suction (with filter) Clean water system Operating light & arm Complete electric dental chair Headrest for adult and children Foot controller Features: All the handpieces tubing is made in USA Metal coated paint Anti-retraction valves to prevent cross contamination system Flush system Radius system Options: Imported high speed air turbine handpieces Imported low speed air motor handpieces Ultrasonic scaler 2.1 Dental chair 2.1.1 limited weight of the chair ≤ 135kg, can be up and down, no suddenly jumped phenomenon 2.1.2 minimal height of the seatrest: 380~810mm. 2.1.3 headrest can bear 300N backward power after locking 2.2 Treating system 2.2.1 standard configuration of the system Driving motor Dental lamp Glass cuspidor Down hung handpiece operating system Chinese syringe tube and American handpiece tube 2.3 Handpiece compatibility This delivery system is designed to be compatible with air dirven handpieces only that comform to ISO 14457 and obtain the CE marking with notified body number. The handpieces which are mentioned below in the use manual are air dirven handpieces. For the air driven handpiece, tubing is available in either 4-hole Midwest tubing or 3-hole Borden tubing. The end user will have specified the preferred type prior to ordering from the factory. It is responsibility of the end user to procure appropriate handpieces for use with this delivery system. Certain countries may have particular regulation regarding which handpieces are acceptable for use; e.g. countries in the European Union require handpieces which meet the requirements of the Medical Devices Directive 93/42/EEC. See your local dealer for additional information. 2.4 Suction saliva head The suction saliva head was not provided by Sunlight. Must buy the suction saliva head by yourself. Beyond that, the suction saliva head should have good biological compatibility and meet the ISO 10993 series standard. 3.1 Intended Use: The treatment unit serves for diagnosis, therapy and dental treatment of humans by skilled professionals. 3.2 Prohibitions and Contraindication Treatment with curing light mini LED: •Looking to the LED light emission cause eye damage. •Curing light should not be used in people who suffer or have suffered Photobiological reactions or in individuals who are currently treated with drugs that increase the sensitivity. Side effect: The side-effects of Dental Units are the damage of operating light to eyes and skin and teeth damaged during water washing whose advantages far outweigh the disadvantages however. Therefore, from literature review and the state of art it’s acceptable for possible risks of Dental Units. The unit is made of dental chair and delivery system. 5.1 dental chair is made of driving system, control system, seatrest, backrest and headrest; 5.2 delivery system is made of cuspidor and the box, treating tray, handpiece, dental light, the arm of the tray, the are of the light, handpiece control and suction system. 5.3 treating tray is made of syringe, viewer, handpiece tubings and adaptor, valves and plastic covers; 5.4 dental light is made of switch, bulb, reflector, cover and frame; 5.5 foot control is made of valves, covers and tubings; 5.6 suction system is made of suction and saliva ejectors, tubings, suction and saliva heads. NOTE: Dental chair surface and arm rest are applied parts.
read more
New Arrival China Dental Phantom For Sale -
 Hi... New Arrival China Dental Phantom For Sale -
 Hi...
01

New Arrival China Dental Phantom For Sale - Hi...

2016-01-08
Designed for the simulation of clinical education Designed for the simulation of clinical education, help students develop the right operating posture in the pre-clinical study, master ergonomic skills and then smoothly transition to real clinical treatment. With JPS FT-III dental teaching simulation system, students learn right from the start, under more realistic conditions: •In a pre-clinical environment, students learn using standard treatment centre components and do not have to adjust to new equipment later in their education •Optimum treatment ergonomics with height-adjustable dentist and assistant elements •Best protection of student health, with integrated, continuous and intensive disinfection of internal water-lines •New design: dual instrument tray, makes four-hand operation come true . •Operation light: the brightness is adjustable. With different type teeth mode Manikin comes with magnetic articulator , it is compatible with different type teeth model Imitate real clinical environment. Electric motors drive the movement of the manikin----imitate real clinical environment. Easy to clean Auto reset function of manikin system- provide the cleanliness and utilization of space Artificial marble top is easy to clean Two preset position keys Two preset position keys : S1 , S2 Automatic reset key : S0 Can be set highest and lowest position With emergency stop function Hommization Suction water bottle Suction water bottle is designed to be removed and installed very easily ,improve study efficiency a lot. JPS Dental simulation experts, reliable partners, sincere forever!
read more
Hot sale Dental Bib Clip -
 Planmeca Promax 2D ... Hot sale Dental Bib Clip -
 Planmeca Promax 2D ...
01

Hot sale Dental Bib Clip - Planmeca Promax 2D ...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
Hot New Products Dental Chair Price -
 High Qua... Hot New Products Dental Chair Price -
 High Qua...
01

Hot New Products Dental Chair Price - High Qua...

2016-01-08
1.Quiet and smooth two way with super soft medical ultra leather hydraulic patient chair 2. Articulating dual axis headrest 3.Four operator programmable position 4.Swing down armrest 5.LCD screens display aluminum casting base instrument tray with touch pad 6.Three handpiece automatic control& 2pcs three way syringe 7.Three axis led operating light with sensor 8.Electric controlled timed bowl rinse and cup filler 9.Swing arm ceramic bowl with touch button water activator 10.Sidebox with self-contained water system 11.Telescoping assistant arm with touch pad 12.Autoclavable standard HVE leaver valve with tubing 13.Autoclavable saliva ejector leaver valve with tubing 14.Asepsis three-way air/water syringe with tubing 15.Memory setting function foot control 16.Deluxe Dentist stool 1.Cast aluminum with steel reinforcement 2.LCD screens displays air/water pressures, water temperature,self contained clean water system / city water option. Along with date, time, and alarm setting 3.Synchronized back&seat movement 4. Safety emergency stop control device 5. Trendelenburg position 6. 30° left to right seat rotation 7. System anti-retraction valves to prevent cross contamination 8. Load capacity 250Kg 3-axis LED light with sensor. LED direct-injection dental lamp with universal rotating joint adjustment, switch with sensor and induction light intensity adjustment. Spittoon flushing and mouthwash cup water injection mode using 12V solenoid valve control, flow control accuracy. Intelligent memory set control, arbitrary adjustment of water cup and spittoon flush way and time. The instrument tray is connected with the lifting arm with a pneumatic self-locking position device. The shell is die-cast by aluminum alloy, and the horizontal alignment of the instrument tray can be adjusted arbitrarily. Equipped with LCD electronic screen, display information including water/air pressure, water temperature, cooling water conversion and working time, etc. Memory setting function foot control
read more
Excellent quality Disinfection Cabinet -
 High ... Excellent quality Disinfection Cabinet -
 High ...
01

Excellent quality Disinfection Cabinet - High ...

2016-01-08
Designed for the simulation of clinical education Designed for the simulation of clinical education, help students develop the right operating posture in the pre-clinical study, master ergonomic skills and then smoothly transition to real clinical treatment. With JPS FT-III dental teaching simulation system, students learn right from the start, under more realistic conditions: •In a pre-clinical environment, students learn using standard treatment centre components and do not have to adjust to new equipment later in their education •Optimum treatment ergonomics with height-adjustable dentist and assistant elements •Best protection of student health, with integrated, continuous and intensive disinfection of internal water-lines •New design: dual instrument tray, makes four-hand operation come true . •Operation light: the brightness is adjustable. With different type teeth mode Manikin comes with magnetic articulator , it is compatible with different type teeth model Imitate real clinical environment. Electric motors drive the movement of the manikin----imitate real clinical environment. Easy to clean Auto reset function of manikin system- provide the cleanliness and utilization of space Artificial marble top is easy to clean Two preset position keys Two preset position keys : S1 , S2 Automatic reset key : S0 Can be set highest and lowest position With emergency stop function Hommization Suction water bottle Suction water bottle is designed to be removed and installed very easily ,improve study efficiency a lot. JPS Dental simulation experts, reliable partners, sincere forever!
read more
Low price for Dental Equipment Suppliers -
 Mob... Low price for Dental Equipment Suppliers -
 Mob...
01

Low price for Dental Equipment Suppliers - Mob...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
China Cheap price Barrier Film -
 Portable X-ra... China Cheap price Barrier Film -
 Portable X-ra...
01

China Cheap price Barrier Film - Portable X-ra...

2016-01-08
This portable dental X-ray unit is high frequency machine. The body is small, light weight and nearly no radiation. It has excellent image quality, portable storage, save more space. It uses high frequency and DC international power supply. All of the components installed in the central PC board concentrated. Shock, set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. There are also manual buttons installed on the surface of shell, as well as batteries and charges. This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. It also can connect with sensor, is great convenience. Checking and Security !  Caution: Please learn relative security measures and functions given in the file or on the unit. * Using the products after checking battery and the location of the device, make sure that is operates properly. * Checking all the power cords whether correctly and connected formally. * Operating the device in the designated order. * Recheck the cone connect with the patient’s face closely. * Keep the device and the cone clean. * Please use or operate the device and parts after taking a necessary periodic inspection. * If you discover some difference in the sensor images even if you inspected its x-ray exposure time in the same way as before, then it means that the radiation of x-ray is abnormal, you must stop using it immediately and allow it to be inspected. * Don’t use or store near the place which is possible to fire. * Don’t use or store where air pressure or temperature or moisture exceeds range. * Keep good ventilation and avoid direct sunlight, protect against the eroding of dust and corrosive air. * Don’t use or store near to chemicals or combustible gas. Tube voltage 60KV Tube current 1.5mA Exposure time 0.1--2.0s Frequency 30KHz Rate power 60VA Distance from skin to cone 130mm Tube focus 0.3mm*0.3mm Battery DC14.8V  6400mAh Charger input voltage AC100V-240V±10% Output voltage DC16.8V Ambient temperature 5℃~40℃ Relative temperature <75%RH Net weight 2.5KG Gross weight 3.5KG Size(mm) 138*165*185 Package size(mm) 365*330*265
read more
Cheap PriceList for Dental OPG X Ray -
 Mobile ... Cheap PriceList for Dental OPG X Ray -
 Mobile ...
01

Cheap PriceList for Dental OPG X Ray - Mobile ...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more