Leave Your Message
Products

Products

Products Categories
Featured Products
Good quality Cotton Roll -
 Mobile Stand Dental... Good quality Cotton Roll -
 Mobile Stand Dental...
01

Good quality Cotton Roll - Mobile Stand Dental...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Manufacturer for Dental Suture -
 Mobile Stand ... Manufacturer for Dental Suture -
 Mobile Stand ...
01

Manufacturer for Dental Suture - Mobile Stand ...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Chinese Professional Gutta Percha Points -
 Por... Chinese Professional Gutta Percha Points -
 Por...
01

Chinese Professional Gutta Percha Points - Por...

2016-01-08
This portable dental X-ray unit is high frequency machine. The body is small, light weight and nearly no radiation. It has excellent image quality, portable storage, save more space. It uses high frequency and DC international power supply. All of the components installed in the central PC board concentrated. Shock, set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection. There are also manual buttons installed on the surface of shell, as well as batteries and charges. This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery. It also can connect with sensor, is great convenience. Checking and Security !  Caution: Please learn relative security measures and functions given in the file or on the unit. * Using the products after checking battery and the location of the device, make sure that is operates properly. * Checking all the power cords whether correctly and connected formally. * Operating the device in the designated order. * Recheck the cone connect with the patient’s face closely. * Keep the device and the cone clean. * Please use or operate the device and parts after taking a necessary periodic inspection. * If you discover some difference in the sensor images even if you inspected its x-ray exposure time in the same way as before, then it means that the radiation of x-ray is abnormal, you must stop using it immediately and allow it to be inspected. * Don’t use or store near the place which is possible to fire. * Don’t use or store where air pressure or temperature or moisture exceeds range. * Keep good ventilation and avoid direct sunlight, protect against the eroding of dust and corrosive air. * Don’t use or store near to chemicals or combustible gas. Tube voltage 60KV Tube current 1.5mA Exposure time 0.1--2.0s Frequency 30KHz Rate power 60VA Distance from skin to cone 130mm Tube focus 0.3mm*0.3mm Battery DC14.8V  6400mAh Charger input voltage AC100V-240V±10% Output voltage DC16.8V Ambient temperature 5℃~40℃ Relative temperature <75%RH Net weight 2.5KG Gross weight 3.5KG Size(mm) 138*165*185 Package size(mm) 365*330*265
read more
PriceList for Dental Bib -
 Apixia Digital PSP ... PriceList for Dental Bib -
 Apixia Digital PSP ...
01

PriceList for Dental Bib - Apixia Digital PSP ...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more