Leave Your Message
Products

Products

Products Categories
Featured Products
China Cheap price Barrier Film -
 Planmeca Prom... China Cheap price Barrier Film -
 Planmeca Prom...
01

China Cheap price Barrier Film - Planmeca Prom...

2016-01-08
Planmeca ProMax® is a complete maxillofacial imaging system. The design and operation principles are based on the latest scientific research, technological  innovations and the most demanding needs of modern-day radiology. Advanced technology •  Autofocus positions the focal layer automatically for perfect panoramic images •  Dynamic Exposure Control (DEC) measures the patient’s radiation transparency and automatically adjusts exposure values •  Patented SCARA (Selectively Compliant Articulated Robot Arm) technology guarantees an anatomically correct imaging geometry for clear, error-free images •  Easy upgrades – add cephalostat or 3D imaging capability at any time Effortless use •  Full-view patient positioning with triple-laser patient positioning lights •  Side entry for comfortable access •  Easy-to-use graphical interface •  Versatile Planmeca Romexis® 2D imaging software •  TWAIN support and full DICOM compliance Planmeca ProMax X-ray unit provides a wide range of extraoral imaging modalities: panoramic imaging for dental arch maxillary sinus imaging temporomandibular joint imaging 2D linear tomography cephalometry  Open positioning and easy use Free view to the patient from all directions Three laser positioning laser beams Easy access also for wheelchair patients Motorized patient positioning and temple supports Autofocus feature makes the positioning of the focal layer automatically. Autofocus takes first a short, low-dose scout image for searching landmarks and calculating the focal layer with the help of a special neural network algorithm. The user can monitor the suggested focal layer adjustment both on the control panel and on the image acquisition preview. The focal layer adjustments can be amended, or the user can simply accept the adjustments and continue to the final exposure. Dynamic Exposure Control (DEC) adapts the whole imaging chain individually for each patient's physio-anatomical characteristics to produce the optimal contrast and density. Both the X-ray source and the image receptor are automatically adjusted to produce the optimum image quality. Interactive, informative and intuitive colour TFT graphic user interface (GUI) Technical factors and selected programs digitally displayed Image preview Optimised image geometry and constant magnification Optimised image geometry and constant magnification Adjustable form of focal trough Automatic compensation for the cervical vertebrae shadow Full digital control Re-programmable flash EPROM Microprocessor controlled self-diagnostic control system with clear help guiding to correct use and error messages announcing hardware or software problems Constant potential, microprocessor controlled resonance mode generator Very high operating frequency 80 – 150 kHz Maximum ripple 670 Vpp (0.4%, 84 kV) Ultra short rise time, < 3 ms Very wide exposure parameters range, 1 – 16mA / 54 – 84 kV2(5) Low patient dose Universal power input including Power Factor Corrector, mains voltage fluctuations automatically compensated Reliable mechanical construction Small size and light weight, total weight 113 kg (249 lbs) Unique 3 joint SCARA (Selectively Compliant Articulated Robot Arm) technology enables complicated movements and versatile imaging geometries, smooth and quiet micro-step motors Telescopic body column without counterweight. Maximum height adjustable. Automatic four blade primary collimator Available as wall-mounted or free standing  Imaging mode: Basic panoramic programs Horizontal and Vertical segmenting Bitewing panoramic program Tomography: Digital tomography, Transtomography Child mode in all imaging programs to reduce the dose and to optimise the imaging geometry Cephalostat Planmeca ProCeph “one shot” cephalostat Digital Ceph Dimax4 (2 fixed sensors or 1 movable sensor) DEC (Dynamic Exposure Control): Panoramic DEC Cephalostat DEC Autofocus Additional features: Accessory cabinet 
read more
Good quality Expendable Items In Dentistry -
 J... Good quality Expendable Items In Dentistry -
 J...
01

Good quality Expendable Items In Dentistry - J...

2016-01-08
Meeting to EN13060 European standard With pre-post vacuum Quick cycle only 10-12min LED display User friendly interface Double locking system Easily accessible water tank 2 trays, max 5 optional Multiple languages Power: 1500W Size: 414*365*530mm Tray size: 147*265mm Cavity size: Ό170x320mm 1.Microcomputer control system for automatic check; 2.With precise control, the temperature can be controlled within ¹ 0.5 during sterilizing 3.Friendly operation interface, simply and easy 4.B&D test, vacuum test, convenient for machine behave test 5.Automatical record of the time of sterilization beginning &end. Clean the inner pipe automatically for avoiding jam after every 6.100 times of cycles. 6.The dry time is adjustable according to your will 7.The machine is dual-purpose, not only for instruments,but also for cotton, on dry condition 8.With a LED display 9.Adjustable date&time&language mode according to your will 10.Opened reservoir, convenient for cleaning, avoiding chloramphenicol alive 11.Water quality sensor can test the quality of distilled water, reduce the failure rate 12.One-piece chamber is made of imported 304 stainless steel 13.Safety valve ensure the chamber can release the pressure safely at emergency 14.Double doors locking-system, mechanical lock with electrical lock,the machine can't open until the pressure turn 0 15.Multi-safety protection system, which can ensure the safety of the operator 16.Air-conditional heat removal system, prevent the machine from over-heating 17.Adopt the ABS plastic, whole model produce 18.The machine plane can adjust by adjustable pad, provide a gradienter for free 19.Optional printer, with a internal USB module as standard collocation to record the sterilization process
read more
OEM China Dental Handpiece Motor -
 Apixia Digi... OEM China Dental Handpiece Motor -
 Apixia Digi...
01

OEM China Dental Handpiece Motor - Apixia Digi...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more
Wholesale Price Base Plate Wax -
 Apixia Digita... Wholesale Price Base Plate Wax -
 Apixia Digita...
01

Wholesale Price Base Plate Wax - Apixia Digita...

2016-01-08
LASER FAST IMAGE PROCESSING Imaging is fast and simple. The smart top-loading design harnesses the power of gravity for simple loading and fuss-free use. In just a short time, the crystal clear radiograph appears on the computer screen, ready for viewing. Simply insert the next exposed plate when ready. FLEXIBLE IN MORE WAYS THAN ONE The Apixia DIGITAL PSP Scanner packs tremendous imaging power into a small package. It is tiny enough to fit into the most crowded dental operatories for handy chair-side use. Imaging with Phosphor plates offers all the flexibility and patient comfort of film, combined with the immediacy and environmental benefits of digital radiography. COMFORTABLE & REUSABLE PHOSPHER PLATES Imaging with Phospher Plates offers all the flexibility and patient comfort of film. Phospher plates are reusable a countless number of times to maximize your investment. 4 optional plate sizes allows for optimum size selection for each patient. SMART AND SIMPLE TOP-LOADING DESIGN Special top-loading design allows for easy image scanning. Just insert and scan any size plate for any type of clinical situation. Quick and easy scanning for easy image viewing on a computer display. 1.Small Tabletop Design 2.High Resolution Scans in a Fraction of the Time 3.Automatic In-line Eraser 4.Powerful, Easy-To-Use Software Included 5.Value-Priced for any Dental Practice Minimum Requirement for Computer Configuration: Windows 7/Windows 8/VISTA/XP (32, 64Bit) 1GB RAM Pentium 4 CPU or much advanced USB 2.0 transmit CD/DVD drive Resolution: >1024*768 40GB for hard drive space High resolution image display HD LCD This machine does not include the computer Digirex Psp Imaging Scanner Specification: Voltage: AC 100-240V, 50/60Hz Scanning time: 10s Resolution: 17 lp/mm Transfer way: USB 2.0 Size of digital X-ray plate: 0# 2# (1# 3# is optional) Built-in cleaning device: Automatic Size: 258*138*183mm Weight: 3.6kg
read more
2021 Latest Design Lubricate Machine -
 Mobile ... 2021 Latest Design Lubricate Machine -
 Mobile ...
01

2021 Latest Design Lubricate Machine - Mobile ...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
2021 High quality Hydraulic Dental Chair -
 Hig... 2021 High quality Hydraulic Dental Chair -
 Hig...
01

2021 High quality Hydraulic Dental Chair - Hig...

2016-01-08
1.Quiet and smooth two way with super soft medical ultra leather hydraulic patient chair 2. Articulating dual axis headrest 3.Four operator programmable position 4.Swing down armrest 5.LCD screens display aluminum casting base instrument tray with touch pad 6.Three handpiece automatic control& 2pcs three way syringe 7.Three axis led operating light with sensor 8.Electric controlled timed bowl rinse and cup filler 9.Swing arm ceramic bowl with touch button water activator 10.Sidebox with self-contained water system 11.Telescoping assistant arm with touch pad 12.Autoclavable standard HVE leaver valve with tubing 13.Autoclavable saliva ejector leaver valve with tubing 14.Asepsis three-way air/water syringe with tubing 15.Memory setting function foot control 16.Deluxe Dentist stool 1.Cast aluminum with steel reinforcement 2.LCD screens displays air/water pressures, water temperature,self contained clean water system / city water option. Along with date, time, and alarm setting 3.Synchronized back&seat movement 4. Safety emergency stop control device 5. Trendelenburg position 6. 30° left to right seat rotation 7. System anti-retraction valves to prevent cross contamination 8. Load capacity 250Kg 3-axis LED light with sensor. LED direct-injection dental lamp with universal rotating joint adjustment, switch with sensor and induction light intensity adjustment. Spittoon flushing and mouthwash cup water injection mode using 12V solenoid valve control, flow control accuracy. Intelligent memory set control, arbitrary adjustment of water cup and spittoon flush way and time. The instrument tray is connected with the lifting arm with a pneumatic self-locking position device. The shell is die-cast by aluminum alloy, and the horizontal alignment of the instrument tray can be adjusted arbitrarily. Equipped with LCD electronic screen, display information including water/air pressure, water temperature, cooling water conversion and working time, etc. Memory setting function foot control
read more
New Fashion Design for Cheap Dental Supplies -
... New Fashion Design for Cheap Dental Supplies -
...
01

New Fashion Design for Cheap Dental Supplies - ...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Good Quality Dental Equipment for Training -
 H... Good Quality Dental Equipment for Training -
 H...
01

Good Quality Dental Equipment for Training - H...

2016-01-08
Designed for the simulation of clinical education Designed for the simulation of clinical education, help students develop the right operating posture in the pre-clinical study, master ergonomic skills and then smoothly transition to real clinical treatment. With JPS FT-III dental teaching simulation system, students learn right from the start, under more realistic conditions: •In a pre-clinical environment, students learn using standard treatment centre components and do not have to adjust to new equipment later in their education •Optimum treatment ergonomics with height-adjustable dentist and assistant elements •Best protection of student health, with integrated, continuous and intensive disinfection of internal water-lines •New design: dual instrument tray, makes four-hand operation come true . •Operation light: the brightness is adjustable. With different type teeth mode Manikin comes with magnetic articulator , it is compatible with different type teeth model Imitate real clinical environment. Electric motors drive the movement of the manikin----imitate real clinical environment. Easy to clean Auto reset function of manikin system- provide the cleanliness and utilization of space Artificial marble top is easy to clean Two preset position keys Two preset position keys : S1 , S2 Automatic reset key : S0 Can be set highest and lowest position With emergency stop function Hommization Suction water bottle Suction water bottle is designed to be removed and installed very easily ,improve study efficiency a lot. JPS Dental simulation experts, reliable partners, sincere forever!
read more
Factory Outlets Water Distiller -
 Mobile Stand... Factory Outlets Water Distiller -
 Mobile Stand...
01

Factory Outlets Water Distiller - Mobile Stand...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
Lowest Price for Dental Industry -
 Mobile Stan... Lowest Price for Dental Industry -
 Mobile Stan...
01

Lowest Price for Dental Industry - Mobile Stan...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more