Leave Your Message
Products

Products

Products Categories
Featured Products
18 Years Factory Combined Dental Cabinets -
 Mo... 18 Years Factory Combined Dental Cabinets -
 Mo...
01

18 Years Factory Combined Dental Cabinets - Mo...

2016-01-08
1 Use the intermational advanced technology 2 high-efficiency and clear imaging, low leaking radiation is only 1% of national standard 3 Light touched button, controled with microcomputer, only press one button to select the exposue parameter, cibvebuebt  fast and accurately 4 Developing in light room, image in one minute, the doctor can diagnose conveniently for maximum 5 Pneumatic up-down seat, more convenient and more comfortable 6 It is for the use of the digital imaging system of mouth Specifications Power supply: 220V±10%,50HZ,1KVA Tube voltage 70KV Tube current 8mA Focus size 0.8mm or 0.4mm(as per demand of end-user) Total filtration 2.5mmAL Exposure time 0.2-4s Leak radiation: outside one meter≦0.002mGy/h,(national standard:0.25mGy/h) Package size: 152*57*26(cm) Net weight: 57kg 1. In order to ensure safety in operation and use, good ground lead must be installed well. 2. Because small X-ray machine’s thermal capacity is limited, attention should be paid to making the machine work intermittently. 3. Only during exposure process this machine will produce X-rays. It won’t produce X-rays in power-off state, neither in power-on state as long as not in exposure. 4. If any unforeseen circumstances occur during correct use, operators should cut off the power immediately and stop using the machine. It cannot be used again until it is overhauled and qualified. 5. Before leaving the factory, each X-ray device is equipped with an additional filter plate with the following specifications: 1.0/0.5mm aluminum sheets. 6. Every time when disassembling the machine, disassemble the head first and then other parts. 8. Every time after using the machine, recover the cross arm to the highest point, and then place the machine head in an equilibrium position. 9. Every time after using, sterilize and clean beam tube end that contacts the patient with medical alcohol. 10. Clean the machine surface with a dry cloth every week and inspect whether the connectors contact well. 11. Pay attention to machine maintenance. Check whether the indicator lights, display, rotary knob, switch, and remote control work normally; whether the X-ray source modules leak oil; whether when X-ray source modules expose produces any abnormal noise; or whether fixed screws in the mechanical part loose, and the like. 13. The rated capacity of the machine is 1.1kw. Please select power supply or power grid with a power supply capacity greater than 1.5kw. If network voltage in this region is abnormal, we recommend matching 1.5KW or higher industrial voltage stabilizer, to prevent damage to the machine and reduced machine life due to abnormal voltage.
read more
2021 High quality Dental Suction Unit -
 AM100 ... 2021 High quality Dental Suction Unit -
 AM100 ...
01

2021 High quality Dental Suction Unit - AM100 ...

2016-01-08
Voltage: 220V-240V/50HZ-60HZ         Power:400W          Revolution:3000r.p.m/50HZ; 3000r.p.m/60HZ Scope of timing:4-16s Mode of Memory:5 kinds Automatic computer control & Numeral display 5 pre-set programs Fit for different moulage material and different mixed dosage 1. Imported motor, low noise and long service life 2. Microcomputer control, safe and reliable operation; 3. After mixing, the impression material has no bubbles, good elasticity, not easy to deform, and mold taking is clearer; 4. The setting time range is long, within 1-24 seconds, the user can choose according to the characteristics of different impression materials; 5. Three kinds of computer memories can be set according to user needs (the factory setting is 8 seconds "one spoon of powder", 10 seconds two spoons of powder", 12 seconds "three spoons of powder">; 6. The internal temperature control of the product is reliable, and it can work continuously for a long time without affecting the production of impression materials; it runs with low noise and is easy to operate. (1) There is a vent hole on the top of the mixing bowl cover. Please clean it to ensure that it is not blocked by impression powder and other sundries. (2) The weight of each mixing (total weight of water and impression powder) should be 25g-75g. If the weight of the mixture is out of this range, the noise of the machine will increase, and there will even be abnormal noises such as impacts, which may damage the machine in severe cases. (3) The optimal mixing weight designed for this machine is 58g , which is the best state of the machine at this time. (4) For the ratio of impression powder and water during mixing, please refer to the standard of the impression powder manufacturer. The supplied water bottle can help measure the amount of water required. Unscrew the bottle body and fill it with mixing water. After tightening, squeeze the bottle body by hand to measure the amount of water (you can also use the special instrument provided by the impression powder manufacturer to measure. According to our experience, a slight increase in the proportion of water will make The mixed impression powder is more delicate, but this will slightly increase the curing time). (5) The temperature of the stirring water should be 10-20°C, otherwise the curing time will be shortened, which is not conducive to operation (especially in summer).
read more